- To protect the steel reinforcement bars ( rebar’s ) from environmental effects to prevent their corrosion.
- To provide thermal insulation, which protects the reinforcement bars from fire.
- To give reinforcing bars sufficient embedding to enable them to be stressed without slipping.
Concrete Cover for Slab:
Why we provide Concrete Cover?
Covering is provided to arrest the attack of corrosion. Reinforcement is prone to corrosion and fire for atmospheric conditions. If the proper cover isn’t implemented then there is more chance of corrosion and cracks in hardened RCC.
Covering is provided For every element of the building (Slabs, Beams, footings) where the reinforcement is used. In order to maintain the proper arrangement of reinforcement and to provide a covering for reinforcement. covering blocks are used.
1. Concrete Cover in Columns / Beams:-
#1 Below is the top view of a column ( the Same principle is applied for beams too).
Images are copyrighted. Mention source if you use this image in your blog/website
From the above figure, The length and Width of the column are 0.5m and 0.45m. It satisfies the second condition in the above table. Then, the covering for reinforcement in the column is 0.050m from all sides and same reinforcement is designed accordingly. The Dimensions of Reinforcement in the column are 0.40m and 0.35m.
#2:- Suppose the length and width of the column are 0.40 and 0.25. From the table, It satisfies both the conditions (2) & (1). Don’t apply two conditions for a single column. Covering should be Symmetrical. Consider the least dimension from the two dimensions. In below figure least dimension is 0.25. For 0.25m the covering of 0.025m is provided. Therefore the covering of 0.025m is provided in all the sides. Hence, dimensions of reinforcement is 0.35m and 0.20m
2. Concrete Cover for Slabs: –
From the below figure the length and width of the slab are 1.3m and 1.0m. As per the above table, the covering of 0.1m is provided if the length of the bar is more than 0.6m. Apply the same condition as mentioned. The covering of 0.1m is provided from all the sides of the slab.
3. Concrete cover for footings:-
As per the below figure the dimensions of Footing are 0.7m and 0.6m. To length and width of Mesh (reinforcement) used in footings are obtained by deducting the cover. Apply the same principle as above, the below footing is fallen under (3) condition. As per the condition, a concrete cover of 0.1m is deduced from all the sides. Hence, the dimensions of reinforcement are 0.5m and 0.4m.
Dial gauges are used to measure the flatness and inclination of objects. It is used to check round bar roundness. It checks the flatness of an object as compared to the flatness of the standard object.
ReplyDeleteThis comment has been removed by the author.
ReplyDeleteHow Many Gallons Is My Septic Tank: The formula is length (feet) x width (feet) x 1 foot x 7.5 gallons, which is the volume for 1-foot depth. To find the volume for 1 inch I divide the volume by 12 to give me gallons per inch.
ReplyDeleteList of Glass Manufacturers in India.
ReplyDelete1. Asahi India Glass Ltd
2. Saint-Gobain India Pvt Ltd
3. Borosil Renewables Ltd
4. La Opala RG Ltd
5. Hindustan National Glass & Industries Limited (HNGIL)
6. Empire Industries Limited
7. Haldyn Glass Limited
8. Binani Industries Limited (BRAJ Binani Group)
9. Nile Limited
10. Sejal glass
Cracked Tile Foundation Problem: Tile cracks can be a sign of a foundation issue, but it can also just be a normal crack. So it's best for us to do a professional inspection. That said, a lot of variables can also come into play since flooring can be damaged due to the type of soil, degree of moisture and weather conditions in your area.
ReplyDelete